High Resistance Grounding System Advantages


* Keeps plants up and running 24/7/365

* Safer for your employees, equipment and your plant

* Easy to locate fault

* Easy to install



PowerKeep is an Excellent Choice for a Wide

Range of High Resistance Grounding Applications:

Process Industries 

Steel Mills 

Mining Operations 

Pulp & Paper Mills 

Power Distributors 

Internet Service Providers 


"PowerKeep" is a registered trademark ® of Gratek CONTROLS CO.



Features & Capabilities


* Ideal for the continuous process industries where you do not want the process to stop on the first fault

* Offers protection to transformers, generators and drives from ground faults. Low probability of mechanical

   damage to transformer when using high resistance grounding

* Available to 6.6 KV

* 600v class packages available as kits



Grounding Comparison Chart

         

        Standard Practices For Industrial Plants

Voltage

 

    600 volts and lower

     

     

    3.3 to 24 kv

Grounding Method

 

    Solid Grounding & High-Resistance

    Grounding

     

    Low Resistance Grounding

NOTE: A recent trend on 600-volt and lower systems has been to use high resistance grounding with all the inherent advantages it has to offer.




    Comparative Benchmarks for Various Grounding Methods

         

        Methods of System Grounding

Characteristics

Ungrounded

Solid Ground

Low Resistance

Ground

High Resistance

Ground

Susceptible to Transient overvoltages

WORST

GOOD

GOOD

BEST

Under fault conditions(line-to-ground) Increase of voltage stress

POOR

BEST

GOOD

POOR

Arc Fault Damage

WORST

POOR

GOOD

BEST

Personnel Safety

WORST

POOR

GOOD

BEST

Reliability

WORST

GOOD

BETTER

BEST

Economics'(Maintenance costs)

WORST

POOR

POOR

BEST

Plant continues to operate under single line-to-ground fault

FAIR

POOR

POOR

BEST

Ease of locating ground faults(time)

WORST

GOOD

BETTER

BEST

System Coordination

NOT POSSIBLE

GOOD

BETTER

BEST

Upgrade of ground system

WORST

GOOD

BETTER

BEST

Two voltage levels on same system

NOT POSSIBLE

POSSIBLE

NOT POSSIBLE

NOT POSSIBLE

Reduction in number of faults

WORST

BETTER

GOOD

BEST

Initial fault current into ground system

BEST

WORST

GOOD

BETTER

Potential flashover to ground

POOR

WORST

GOOD

BEST

 

    PowerKeep

     High Resistance Grounding

     Keeps Plants Up and Running

     24/7/365

 

     *NEC 규정 접지 및 본딩Bonding 기본 원칙<바로가기>

 

[Products]

MV Switchgears   
LV Switchgears  
Motor Control Centers(MCC)  
PowerKeep High Resistance Grounding Equipments(HRG)   
Derived Neutral Grounding Equipments for 3,300V 4,160V 6,600V Delta System